MAC3 - Generatori d'acqua calda a tre giri effettivi di fumo

Producibilità da 1.000 kW a 10.500 kW. Pressioni di esercizio fino a 6 bar. Temperature fino a 109°

Hot water boiler up to 109°C , with effective three smoke passes construction and totally wet construction. The first smoke pass takes place into the furnace and the second and third ones though the high thickness smoke tubes. This hot water boiler has been built according to the most advanced techniques by highly qualified personal into our factory. The exchange area is particularly vast in order to maintain low specific thermical load and high efficiency with Low NOx emissions. The standard stamped pressure is 6 bar but upon request on higher pressure can be offered. The boiler is already insulated with high density rook wool with a coating based of galvanized steel sheet.