BOILER RANGE

Vertical packaged heater, pressurised, with a three-pass design. The coil is wound in a continuous spiral: the first gas pass takes place in the combustion chamber and the other two between the coils. The heater is designed for temperatures up to 300 °C, using thermal fluid as the heat transfer medium.

Vertical thermal fluid heater

Horizontal packaged heater, pressurised, with a three-pass design. The coil is wound in a continuous spiral: the first gas pass takes place in the combustion chamber and the other two between the coils. The heater is designed for temperatures up to 300 °C, using thermal fluid as the heat transfer medium.

Horizontal thermal fluid heater

Once-through (forced circulation) steam generator in which the water is pumped by one or more feedwater pumps through a single tube, the coil, which forms the heating surface.

Vertical coil-type steam generator

Pressure (bar g): 12 ∼ 30

Once-through (forced circulation) steam generator in which the water is pumped by one or more feedwater pumps through a single tube, the coil, which forms the heating surface.

Horizontal coil-type steam generator

Pressure (bar g): 12 ∼ 30

features a three-pass reverse flame design with a fully wet back. The first and second gas passes take place in the combustion chamber, while the third is through the fire tubes, which are also fitted with turbulators.

Fire tube, reverse flame, low pressure

Pressure (bar g): 1

Pressurised-combustion horizontal fire tube (shell) boiler with full three-pass wet back design, designed by the engineers in our technical department using the most advanced technologies.

Fire tube, three-pass, flat tube plates

Pressure (bar g): 12, 15, 18, 20, 25

Pressurised-combustion horizontal fire tube (shell) boiler with full three-pass wet back design, designed by the engineers in our technical department using the most advanced technologies.

Fire tube, three-pass, flanged tube plates

Pressure (bar g): 12, 15, 18, 20, 25

A three-pass reverse flame design with fully wet back. The first and second passes take place in the furnace, while the third pass is through the fire tubes, which are also fitted with turbulators.

Fire tube, reverse flame

Pressure (bar g): 12, 15

Pressurised-combustion horizontal fire tube (shell) boiler with full two-pass dry back design, designed by the engineers in our technical department using the most advanced technologies. The first pass takes place inside the furnace and the second through the fire tubes.

Fire tube, two-pass