This type of boiler is ideal for users that need a continuous supply of steam, such as companies in the food, chemical and pharmaceutical, textiles, fertiliser, petrochemical (refineries), paper, industrial laundry, beverage, building materials, plastics, rubber and timber sectors, among others.
Only certified materials are used for the pressure vessel, and non-destructive testing (NDT) – radiographic testing of the weld intersections and dye penetrant testing of the fillet welds – is carried out by our qualified technician and verified by a Notified Body. The boiler is CE marked in accordance with the Pressure Equipment Directive (PED) 2014/68/EU (UKCA marking available on request), designed to EN 12953 and fitted with a full set of safety devices.
The tube plates can be either flat and fillet welded, or fully hot-flanged to absorb thermal expansion at varying loads. All joints are carefully submerged-arc welded using manual/automatic procedures.
The external surfaces and headers are insulated with high-density mineral wool (rock wool) (100 kg/m3, clad in aluminium or stainless steel) and finished with special paints to minimise heat losses.
The construction of our boiler is the result of meticulous design and careful selection of the best-performing materials. The pressure vessel, made from high-quality steel, is built in a horizontal cylindrical configuration for strength and long service life. The fully wet back furnace, with no refractory, ensures efficient, even combustion, while the flanged tube plates and welded steel fire tubes offer greater strength and operational safety. High-density mineral wool insulation, with aluminium or (on request) stainless steel cladding, retains the heat inside the boiler and further improves energy efficiency. Every component, from the steel base frame to the inspection doors, is designed for easy maintenance and longevity, making this boiler the ideal choice for anyone looking for reliability and superior performance.
Our optional 24 h unattended operation kit (up to 24 hours between operator checks) includes, in addition to the standard equipment, the following components:
Our optional 72 h unattended operation kit (up to 72 hours between operator checks, in line with BG01) includes, in addition to the standard equipment, the following components: