MVI

A three-pass reverse flame design with fully wet back. The first and second passes take place in the furnace, while the third pass is through the fire tubes, which are also fitted with turbulators.

This type of boiler is ideal for users that need a continuous, steady supply of steam: its large water content allows it to respond to sudden changes in steam demand almost instantly.

The MVI was designed by our technical department using the most advanced technologies to give customers the highest guarantee of reliability and long service life. Only certified materials are used for the pressure vessel, and non-destructive testing (NDT) – ultrasonic testing of the furnace, radiographic testing of weld intersections and welds, dye penetrant testing – is carried out by our qualified technician and verified by a Notified Body.

The boiler is CE marked in accordance with the Pressure Equipment Directive (PED) 2014/68/EU (UKCA marking available on request), designed to EN 12953 and fitted with a full set of safety devices.

All joints are carefully arc welded using manual/automatic procedures. The external surfaces and headers are insulated with high-density mineral wool (rock wool) (100 kg/m3, clad in aluminium or stainless steel) and finished with special paints to minimise heat losses.

Caldaie Melgari: pioneers in sustainable heat

The MVI is available for the production of hot water, high temperature hot water and saturated steam.

Steam output: from 140 kg/h to 5,000 kg/h (F&A 100 °C)

Boiler efficiency: flue gas velocity through the tubes is so high that soot cannot build up, giving a consistent boiler efficiency of over 90% (net CV). With an integral economiser, efficiency rises to around 95%.

Pressure: up to 15 bar g

Fuel: designed to fire both liquid and gaseous fuels. As well as the standard fuels (natural gas, LPG, gas oil), firing on biogas, biomethane, kerosene or heavy fuel oil (HFO) is available on request.

THE KEY BENEFITS FOR YOU

Built from high-quality materials such as P275NH steel, our boiler delivers complete, efficient combustion, optimising your company’s energy performance. Its intelligent design, with a manhole and a handhole for easy inspection, makes maintenance quick and simple and preserves the value of your plant over time. High-density mineral wool insulation and a sturdy steel base frame ensure a long service life and protection against the elements. We also offer tailored solutions to adapt the boiler to the specific needs of your business, guaranteeing efficiency, energy savings and hassle-free installation.

Technical diagram of the MVI steam boiler with numbered components

THE BOILER BODY

The boiler shell is made from high-quality steel for strength and long-term reliability. Its horizontal cylindrical design is engineered to optimise combustion, with a large, well-proportioned furnace that ensures thorough mixing of fuel and combustion air. The boiler also has flanged connections and a manhole for easy inspection and maintenance. Every detail of the boiler shell is designed for efficiency, safety and durability, delivering a product that meets the most demanding performance and reliability requirements.

Steam output FOR all sizes

ANCILLARY EQUIPMENT

  • Valves
    • Main steam stop valve
    • Blowdown valve with isolating valve
  • Control and regulating equipment
    • Steam pressure gauge with three-way gauge cock and test flange
    • Operating pressure switches (two-stage burner) / pressure transmitter for burner modulation (modulating burner)
    • 2 × water level gauges (gauge glasses), each with 2 × isolating cocks (the lower one is a three-way cock for draining and blowdown)
  • Safety devices
    • High-pressure limiter (manual reset)
    • 2 × safety valves
  • Control panel
    • Painted steel enclosure, IP54-rated
    • Door-interlocked main isolator
    • Burner on/off switch
    • Feedwater pump on/off switch
    • Auxiliary circuit transformer
    • Fuses
    • Indicator lights
  • Feedwater system, comprising:
    • Isolating valve fitted directly to the boiler shell
    • Non-return valve connected to the isolating valve
    • Skid-mounted electric feedwater pump with 1 × isolating valve and 1 × non-return valve. The pump is supplied pre-wired and pre-piped on the skid. Flow rate and head comply with all current regulations.

Our optional 24 h unattended operation kit (up to 24 hours between operator checks) includes, in addition to the standard equipment, the following components:

  • 1 × water level controller with probes
  • 2 × low-water level limiter probes

Our optional 72 h unattended operation kit (up to 72 hours between operator checks, in line with BG01) includes, in addition to the standard equipment, the following components:

  • 1 × water level controller with probes
  • 2 × low-water level limiter probes
  • 1 × high-water level limiter probe
  • 1 × boiler water conductivity (TDS) probe
  • 1 × feedwater conductivity probe
  • 1 × automatic bottom blowdown system
  • Tested and approved 72-hour shutdown system: includes a timer that can only be reset once the boiler operator has carried out a set of checks on the boiler.

YOU MAY ALSO BE INTERESTED IN

Get in touch

Our team of experts is always on hand to help you

ALL THE BENEFITS

  • The generous heating surface keeps specific heat flux low and ensures high efficiency even in continuous, high-demand operation.
  • The boiler’s large front inspection door simplifies maintenance and cleaning as well as statutory in-service inspections. Maintenance plays a vital role for your boiler: as well as preserving the value of your plant over time, it is the best protection against the risk of unplanned downtime.
  • The control panel, positioned at a convenient working height, gives easy access to all the boiler’s control systems.
  • The arrangement of the tubes around the furnace ensures even distribution of the flue gases while maintaining the heat flux. Steel or stainless steel turbulators also keep flue gas velocities high enough to guarantee consistently high efficiency.
  • The dry steam produced by the boiler reduces condensate returns through the steam traps in the system and therefore delivers significant energy savings for your business.
  • Before delivery, every Caldaie Melgari steam boiler is rigorously checked to verify its output and efficiency. In addition to non-destructive testing, each boiler undergoes a fired test at the factory to guarantee a high standard of construction and quality.
  • The boiler is delivered ready for connection to the fuel supply, power supply, drains and water circuits, making installation quick and simple.
  • On request, we can offer integrated solutions to improve boiler efficiency and save fuel – for example an economiser, a heat exchanger that recovers residual heat from the flue gases to preheat the feedwater before it enters the boiler, saving energy and reducing fuel consumption. The benefits for your business are tangible: a 3–4% increase in efficiency (up to 5%); a 3–4% reduction in emissions (up to 5%); less waste and excess consumption; and recovery of heat and energy that would otherwise be lost to atmosphere.
  • Fully modulating control of the burner and feedwater pump, managed by PLC (Programmable Logic Controller) and inverter, is available as an option.
  • The boiler is supplied either mounted on a heavy-duty welded steel base frame (skid) for immediate installation, or containerised together with the other boiler house equipment (e.g. water treatment system, deaerator, removable blowdown vessel, etc.).
  • On request, the boiler can be equipped for unattended operation – 24 h / 72 h between operator checks, in line with BG01 – with our dedicated kit (e.g. high-integrity self-monitoring low-water level limiters, self-monitoring high-water level limiter, boiler water TDS controller with probe, feedwater conductivity controller with probe, TDS blowdown valve and automatic bottom blowdown valve).
  • The hard-wearing aluminium cladding (stainless steel on request) protects the boiler from weather damage.
  • On request, we provide support during assembly, installation and commissioning, as well as a spares and emergency service with 24-hour call-out.
  • The boiler can be configured to your exact requirements: a wide range of optional ancillaries is available to tailor the product to any specific request (e.g. economiser, access ladder and walkway, second feedwater pump, sample cooler, water softener with brine tank, etc.).

THE BOILER BODY

  1. High-quality steel pressure vessel, cylindrical and horizontal, with shell, furnace and tube plates in P275NH steel. The pressure vessel is supplied complete with all connections.
  2. The boiler shell has a manhole at the top and a handhole at the bottom for water-side inspection. A rear door gives access for inspection and servicing.
  3. Cylindrical furnace in high-quality steel with fully wet back (water-cooled) reversal chamber, with no refractory. The generously sized furnace ensures thorough mixing of fuel and combustion air for complete, efficient combustion.
  4. Fire tubes in P235GH steel to EN 10216-2, welded to the tube plates.
  5. Fully opening rear smokebox in carbon steel, refractory-lined, directing the flue gases to the flue outlet (flanged, with gasket).
  6. Refractory-lined front smokebox in carbon steel, with hinged doors for fire tube inspection and burner mounting plate.
  7. 100 mm high-density mineral wool (rock wool) insulation (100 kg/m³) with aluminium cladding (stainless steel on request).
  8. Steel base frame for mounting the boiler and its ancillaries.

Download the technical datasheet